Lincoln Navigator: Passive Anti-Theft System (PATS) / Key Programming Using Two Programmed Keys. General Procedures
Programming
NOTE:
This procedure works only if the spare key programming is enabled.
NOTE:
Two previously programmed keys are required to perform this
procedure. All the steps must be completed within 30 seconds.
NOTE:
Make sure all the doors are closed prior to beginning this
procedure and they remain closed until the procedure is complete.
-
Locate the passive key backup starting location. Refer
to the Owner Literature for the passive key backup starting location.
-
Place the first programmed passive key in the backup starting location. Press the START/STOP button.
-
Wait 5 seconds and then press the START/STOP button.
-
Remove the first previously programmed passive key.
-
Within 10 seconds, place the second previously
programmed passive key in the backup starting location and press the
START/STOP button.
-
Wait 5 seconds and press the START/STOP button.
-
Remove the second previously programmed passive key.
-
NOTE:
See the Owner's Literature for maximum number of keys that can be programmed to the vehicle.
Wait 5 seconds and then place the unprogrammed passive
key in the backup starting location and press the START/STOP button.
-
NOTE:
If the key does not successfully program, wait at
least 10 seconds before attempting to repeat the procedure.
Verify the RKE transmitter operates and the vehicle starts using the new passive key.
Programming
NOTE:
A passive key with a depleted battery(ies) only starts the vehicle when
in the backup starting location. The RKE functionality remains
inoperative until the key battery(ies) is replaced...
Special Tool(s) /
General Equipment
Interior Trim Remover
Removal
Release the clips and remove the floor console front trim panel...
Other information:
Reference Value Symptom Chart
NOTE:
The Reference Value Symptom Chart provides guidance in
selecting the appropriate parameter identification (PID) or measured
signal related to the fault area. Select a symptom from the symptom
chart along with the category number and go to the PID/Measured Signal
Chart...
Programming
WARNING:
Before beginning any service procedure in this
manual, refer to health and safety warnings in section 100-00 General
Information. Failure to follow this instruction may result in serious
personal injury...